Signal Conditioners

SC Series

Signal Conditioners

SC30 Signal Conditioner

For use with Selectra Modulating Valves

Maxitrol’s track mounted signal condi­tioners and M/MR valves can be configured for direct or indirect fired gas appli­ca­tions. They may be field installed on existing equipment or specified for new equipment.

Model Input
  SC11‑A 4–20 mA input
  SC11‑V 0–10 VDC input
  SC11‑B 4–20 mA or 0–10 VDC input (Replaces SC10-A6S2, SC10-V6S2, SC10-B6S1)
  SC11‑S 4–20 mA or 0–10 VDC input with Adjustable Low Fire Start Timer
  SC25S 4–20 mA or 0–10 VDC input with Min and Max Discharge Air Temp Limits and Adjustable Low Fire Start Timer Option (Replaces SC20C-B6S2)
  SC30 0–10 VDC input for Indirect Fired Gas Applications using 2‑Speed Inducers and 2‑Stage Gas Valves
  SC30-SM2 0–10, 2–10 VDC or 0–20, 4–20 mA
  D‑SC1 0–5, 1–5, 0–10 VDC or 1–20, 4–20 mA
SC30 Signal Conditioner

For use with Selectra Modulating Valves

Maxitrol’s track mounted signal condi­tioners and M/MR valves can be configured for direct or indirect fired gas appli­ca­tions. They may be field installed on existing equipment or specified for new equipment.

Model Input
  SC11‑A 4–20 mA input
  SC11‑V 0–10 VDC input
  SC11‑B 4–20 mA or 0–10 VDC input (Replaces SC10-A6S2, SC10-V6S2, SC10-B6S1)
  SC11‑S 4–20 mA or 0–10 VDC input with Adjustable Low Fire Start Timer
  SC25S 4–20 mA or 0–10 VDC input with Min and Max Discharge Air Temp Limits and Adjustable Low Fire Start Timer Option (Replaces SC20C-B6S2)
  SC30 0–10 VDC input for Indirect Fired Gas Applications using 2‑Speed Inducers and 2‑Stage Gas Valves
  SC30-SM2 0–10, 2–10 VDC or 0–20, 4–20 mA
  D‑SC1 0–5, 1–5, 0–10 VDC or 1–20, 4–20 mA

For use with EXA Modulating Valves

The SC40 Series signal condi­tioner, used with the E42H, E52H, and E62H Series modulating gas valves, is designed to modulate atmos­pheric indirect fired heaters with a 2‑speed inducer. Most appli­ca­tions are able to achieve approx­i­mately a 5:1 turndown. The system is easily integrated into existing heater designs. The system’s relia­bility and simplicity greatly reduce the engineering time required to bring a high turndown modulating heater to market.

The SC40-SM2 Series signal condi­tioner, used with the E42, E52, E62 Series modulating gas valves, is designed to modulate atmos­pheric indirect fired heaters that have a sectioned gas manifold and 2‑speed inducer. The sectioned — or split — manifold design operators as two independent manifolds sharing a single 2‑speed inducer. One manifold section is fully modulating, and the other section operates as a 2‑stage. Typical appli­ca­tions achieve a turndown of approx­i­mately 10:1.

Model Input
  SC40 0–10,  2–10 VDC  or  0–20,  4–20 mA
  SC40-SM2 0–10,  2–10 VDC  or  0–20,  4–20 mA
SC40-SM2 Signal Conditioner
SC40-SM2 Signal Conditioner

For use with EXA Modulating Valves

The SC40 Series signal condi­tioner, used with the E42H, E52H, and E62H Series modulating gas valves, is designed to modulate atmos­pheric indirect fired heaters with a 2‑speed inducer. Most appli­ca­tions are able to achieve approx­i­mately a 5:1 turndown. The system is easily integrated into existing heater designs. The system’s relia­bility and simplicity greatly reduce the engineering time required to bring a high turndown modulating heater to market.

The SC40-SM2 Series signal condi­tioner, used with the E42, E52, E62 Series modulating gas valves, is designed to modulate atmos­pheric indirect fired heaters that have a sectioned gas manifold and 2‑speed inducer. The sectioned — or split — manifold design operators as two independent manifolds sharing a single 2‑speed inducer. One manifold section is fully modulating, and the other section operates as a 2‑stage. Typical appli­ca­tions achieve a turndown of approx­i­mately 10:1.

Model Input
  SC40 0–10,  2–10 VDC  or  0–20,  4–20 mA
  SC40-SM2 0–10,  2–10 VDC  or  0–20,  4–20 mA

TitleDescriptionVersionDownload
SC11 Signal Conditioners

Installation Instructions; For direct or indirect fired applications. Drives multiple Selectra valves simultaneously.

🇺🇸 SC11_OEM_MS_EN_11.2017 DownloadPreview
SC11 & SC25S Signal Conditioner

Installation Instructions; Analog signal conditioners convert selectable 0-10 VDC or 4-20 mA control signal to an output level capable of driving one or more Selectra valves.

🇺🇸 SC11S_25S_MS_EN_11.2017 DownloadPreview
SC30 Signal Conditioner

Installation Instrucitons; Converts a selectable 0-10 VDC to a 0-20 VDC signal capable of driving a Selectra valve.

🇺🇸 SC30_MS_EN_09.2012 DownloadPreview
SC30-SM2 Signal Conditioner

Installation Instructions; Used with M420, M520, M620 on atmospheric indirect fired heaters w/sectioned manifold & 2-speed inducer.

🇺🇸 SC30-SM2_MS_EN_12.2020 DownloadPreview
SC40 Series Signal Conditioner

Installation Instructions; Used with E42H, E52H, E62H series modulating valves. Designed for modulate atmospheric indirect fired heaters with 2-speed inducer.

🇺🇸 SC40_MS_EN_12.2020 DownloadPreview
SC40-SM2 Series Signal Conditioner

Installation Instructions; Used with E42, E52, E62 Series modulating vavles. Designed to modulate atmospheric indirect fired heaters with sectioned manifold & 2-speed inducer.

🇺🇸 SC40_SM2_MS_EN_10.2020 DownloadPreview