GF/HF2000/GF1000
Gas & Air Filters
HF2000 Series
Gas and air filters protect downstream controls (e.g. regulators, automatic shut-off valves) from particulate contamination. Recommended for use upstream of fittings, regulators, and controls. Applications for the residential, commercial cooking, process heating, and industrial burner industries.
Certifications
Gas Types
Suitable for natural, manufactured, mixed gases, liquefied petroleum gases, LP gas-air mixtures, sewer gas, air, and gases of EN 437 gas family 1, 2, and 3
Pipe Sizes
NPT Model | ISO 7–1 Model | Pipe Sizes | Connection |
GF40-44… | GF40M-44… | ½”, Rp ½” | Threaded |
GF60-66… | GF60M-66… | ¾”, Rp ¾” | |
GF60-88… | GF60M-88… | 1″, Rp 1″ | |
GF80-1010… | GF80-1010… | 1 ¼”, Rp 1 ¼” | |
GF80-1212… | GF80-1212… | 1 ½”, Rp 1 ½” | |
GF80-1616… | GF80-1616… | 2″, Rp 2″ |
ISO 7–1 Model | Pipe Sizes | Connection |
GF25MF-88… | DN25 | Flanged |
HF2000F80… | DN80 | |
HF2000F100… | DN100 | |
GF125MF-4040… | DN125 | |
GF150MF-4848 | DN150 |
Pipe Sizes
Model | Pipe Sizes |
GF40-44… | ½” |
GF60-66… | ¾” |
GF60-88… | 1″ |
GF80-1010… | 1 ¼” |
GF80-1212… | 1 ½” |
GF80-1616 | 2″ |
HF2000 Series
Gas and air filters protect downstream controls (e.g. regulators, automatic shut-off valves) from particulate contamination. Recommended for use upstream of fittings, regulators, and controls. Applications for the residential, commercial cooking, process heating, and industrial burner industries.
Certifications
Gas Types
Suitable for natural, manufactured, mixed gases, liquefied petroleum gases, LP gas-air mixtures, sewer gas, air, and gases of EN 437 gas family 1, 2, and 3
HF2000 SERIES
- Pipe Sizes:
- Rp ½ to Rp 2 threaded connections according to EN 10226–1 / ISO 7–1
- DN25 to DN150 flanged connections according to ISO 7005–2, PN 16
- Housing Material: Aluminum
- Internal Components Material: Aluminium, elastomer, polypropylene fleece, galvanized wire mesh
- Filter Insert: Particulate contamination that equals or exceeds 50 μm
- Mounting: Suitable for multi-positional mounting, preferably with lid facing down or to the side to facilitate removal of debris during maintenance.
- Construction and Design/Certifications: Function according to DIN 3386, Gas Appliances Regulation 2016/426/EU and Pressure Equipment Directive 97/23/EEC
- Gas Types: Gas family 1, 2, and 3 according to EN 437
- Pressure Tap Connector: Optional, inlet and/or outlet side
- Maximum Inlet Pressure: 100 kPa, 400 kPa, 600 kPa
- Ambient Temperature Range: ‑20 to 80 °C
- Storage and Transport Temperature: ‑50 to 80 °C
GF1000 SERIES
- Pipe Sizes: DN40 to DN65 flanged connections according to ISO 7005–2, PN 16
- Housing Material: Aluminum
- Internal Components Material: Aluminium, elastomer, polypropylene fleece, galvanized wire mesh
- Filter Insert: Particulate contamination that equals or exceeds 50 μm
- Mounting: Suitable for multi-positional mounting, preferably with lid facing down or to the side to facilitate removal of debris during maintenance.
- Construction and Design/Certifications: Function according to DIN 3386, Gas Appliances Regulation 2016/426/EU and Pressure Equipment Directive 97/23/EEC
- Gas Types: Gas family 1, 2, and 3 according to EN 437
- Pressure Tap Connector: Outlet standard, inlet optional
- Maximum Inlet Pressure: 100 kPa, 400 kPa, 600 kPa
- Ambient Temperature Range: ‑20 to 80 °C
- Storage and Transport Temperature: ‑50 to 80 °C