Vent Limiting Devices

Maxitrol vent limiting devices eliminate the need to run vent piping to the outside. They are designed for use indoors and in spaces where limiting the amount of gas escapement due to diaphragm failure is critical. Vent limiting devices should not be used outdoors if they are exposed to the environment. Ball check permits unobstructed inhalation for fast regulator diaphragm response on opening cycle, but limits gas escapement to be within ANSI and EN 88 requirements should a diaphragm rupture.

ModelThreadUse on …
12A041/8″ NPTRV48, RV52, RV53, RV61, R400(S), R500(S), R600(S)
12A091/8″ NPT325–3, 325–3L; OPD48, OPD600
12A343/8″ NPTRV81
12A393/8″ NPT325–5, 325–5L; OPD210D
12A491/2″ NPT325–7A, 325–7AL, 325–9, 325–9L; OPD210E

Vent Protectors

Designed for outdoor applications. Use on vent opening to protect breather hole from rain, snow, dust, insects and other foreign particles.

ModelThreadUse on …
13A30-501/8″ NPT325–3, 325–3L, RV48, RV52, RV53, RV61, R500(S)(Z), R600(S)(Z)
13A31-503/8″ NPT325–5, 325–5L, RV81, 210D
13A32-501/2″ NPT325–7A, 325–7AL, 325–9, 325–9L, RV91, 210E
13A33-103/4″ NPT325–11, 325–11L, 210G, RV111

Vent Limiting Orifice

Orifice hole is on side of body, under head. Fixed orifice equally limits inhalation and escapement.

ModelThreadUse on …
12A061/8″ NPTRV48, RV52, RV53, RV61, R400(S), R500(S), R600(S)

Vent Tube Connectors

Threaded sleeve — two-piece assembly where the nut is tightened inside male connector.

ModelThread
11A03Connects ⅛” female pipe thread to ⅛” O.D. tubing
11A04Connects ⅛” female pipe thread to ¼” O.D. tubing

Threaded sleeve nut — for RV20V

ModelThread
11A085/16–24 threaded sleeve nut for ⅛” O.D. tubing

Compression fitting — where nut and sleeve are slipped over tubing and tightened into fitting body

ModelThread
11A05-42Connects ¼” female pipe thread to ¼” O.D. tubing
11A05-61Connects ⅛” female pipe thread to ⅛” O.D. tubing
11A05-63Connects ⅜” female pipe thread to ⅜” O.D. tubing
11A05-64Connects ½” female pipe thread to ⅜” O.D. tubing

Tamper Proof Seals

Permanent pressure sensitive backed paper. Attempted removal of these seals will destroy the face stock, leaving adhesive residue on surface beneath. Therefore, tampering can be easily detected. Available for all threaded models. Outlet pressure printed on seal.

ModelUse on …
101310RV12, RV20L, RV47, RV48, RV52, RV53, RV61, R400(S)(Z), R500(S)(Z), R600(S)(Z), 325–3, 325–5
101311RV81, RV91, RV111, 210D, 210E, 210G, 325–7A, 325–9

Vent Dampeners

ModelUse on …
KVOP-3325–5, 325–5L
KVOP-4325–7A, 325–7AL, 325–9L

Vent Screens

Brass, 40 mesh screen flame arrestor for insertion in vent outlet. Prevents ignition of gas-air mixture which might be present in upper diaphragm chamber.

ModelThread
13A03-1For ⅛” NPT vent
13A03-2For ¼” NPT vent
13A03-3For ⅜” NPT vent
13A03-4For ½” NPT vent
13A03-6For ¾” NPT vent

Pressure Tap Connector

Pressure tap connector installed as part of the control. It is a hose fitting incorporating a captured sealing means for testing inlet and outlet pressures. This eliminated the need for a special barb fitting.

ModelThread
PF10⅛” NPT

Dust Cap

Used on vent opening to prevent blockage of the breather hole from dust of other foreign particles. Press-in plastic cap.

ModelThread
13A09For ⅛” NPT vent