Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
CATALOG2nd Edition 2015 Maxitrol Company. All Rights Reserved. DRAFT 09.18.2013 2 Service and installation must be performed by a trainedexperienced service technician. All products used with combustible gas must be installed and used strictly in accordance with the instructions of the Original Equipment Manufacturer OEM and with all applicable government codes and regulations e.g. plumbing mechanical and electrical codes and practices. Maxitrol products should be installed and operated in accordance with Maxitrol Safety Warning Instructions. Maxitrol Company is NOT responsible for any errors or omissions in reliance by anyone of any information set forth in this catalog without additional reference to local requirements and applicable ordinances or codes. Other worldwide approvals and certifications available upon inquiry. C US UA.TR.012-13 2015 Maxitrol Company. All Rights Reserved. DRAFT 09.18.2013 60 Vent Tube Connector Threaded sleeve - two piece assembly where the nut is tightened inside male connector. 11A03 connects 18 female pipe thread to 18 O.D. tubing. 11A04 connects 18 female pipe thread to 14 O.D. tubing. Threaded sleeve nut - for RV20V. 11A08 516-24 threaded sleeve nut for 18 O.D. tubing. Compression fitting - where nut and sleeve are slipped over tubing and tightened into fitting body. 11A05-42 connects 14 female pipe thread to 14 O.D. tubing. 11A05-61 connects 18 female pipe thread to 18 O.D. tubing. 11A05-63 connects 38 female pipe thread to 38 O.D. tubing. 11A05-64 connects 12 female pipe thread to 38 O.D. tubing. Vent Limiting Device Optional automatic vent limiting device - ball check permits unobstructed inhala- tion for fast regulator diaphragm response on opening cycle but limits gas escape- ment to within ANSI standards should a diaphragm rupture. NOTEWhenusingtheventlimitingdeviceregulatormustbemountedinahorizontal upright position. 12A04 CSA certified for up to 12 psi 14 w.c. inlet pressure. Use on RV48 RV52 RV53 RV61 R400S R500S R600S regulators. Color - brass. 18 NPT. 12A09 CSA certified for 2 psi LP and 5 psi natural inlet pressure with 325-3 and 325-3L regulators OPD48 OPD600. Color - green. 18 NPT. 12A34 CSA certified for up to 12 psi 14 w.c. inlet pressure with RV81. Color - brass. 38 NPT. 12A39 CSA certified for 2 psi LP and 5 psi natural inlet pressure with 325-5 and 325-5L regulators OPD210D. Color - brass. 38 NPT. 12A49 CSA certified for 2 psi LP and 5 psi natural inlet pressure with 325-7A 325-7AL 325-9 and 325-9L regulators OPD210E. Color - brass. 12 NPT. Satisfies ANSI Standards for both Natural and LP gas. NOTE Vent limiters are not recommended for use in models RV91 RV111 RV131 and 210 Series. Vent Limiting Orifice 12A06 Orifice hole is on side of body under head. Fixed orifice equally limits inhalation and escapement. Use on RV48 RV52 RV53 RV61 R400S R500S R600S regulators. Color- brown. 18 NPT. Satisfies ANSI Standards for both Natural and LP gas. 12A09 11A03 11A08 11A05 12A06 12A39 12A49 ACCESSORIES 2015 Maxitrol Company. All Rights Reserved. DRAFT 09.18.2013 61 Vent Protector Designed for outdoor applications. Use on vent opening to protect breather hole from rain snow dust insects and other foreign particles. NOTEVent protector MUST be mounted in an upright position. 13A15 for 18 NPT vent. For outdoor use in 325-3 325-3L RV48 RV52 RV53 RV61 R500SZ and R600SZ. 13A15-5 for 38 NPT vent. For outdoor use in 325-5 325-5L RV81 210D. 13A25 for 12 NPT vent. For outdoor use in 325-7A 325-7AL 325-9 325-9L RV91 210E. NOTE NOT a vent limiting device. Consult Maxitrol regarding other configurations. Vent Dampener KVOP-3 Used on 325-5 325-5L. KVOP-4 Used on 325-7A 325-7AL 325-9L NOTE Should not be used with vent limiter. Vent Screen Brass 40 mesh screen flame arrestor for insertion in vent outlet. Prevents ignition of gas-air mixture which might be present in upper diaphragm chamber. 13A03-1 for 18 NPT vent. 13A03-2 for 14 NPT vent. 13A03-3 for 38 NPT vent. 13A03-4 for 12 NPT vent. 13A03-6 for 34 NPT vent. Pressure Tap Connector PF10 Pressure tap connector installed as part of the control. It is a hose fitting incorporating a captured sealing means for testing inlet and outlet pressures. This eliminates the need for a special barb fitting. Dust Cap Use on vent opening to prevent blockage of breather hole from dust or other foreign particles. Standard on all L models with 18 threaded vent. 13A09 for 18 NPT vent. Press-in plastic cap. Tamper Proof Seals Permanent pressure sensitive backed paper. Attempted removal of these seals will destroy the face stock leaving adhesive residue on surface beneath. Therefore tampering can be easily detected. Available for all threaded models. Outlet pressure printed on seal. 101310 for RV12 RV20L RV47 RV48 RV52 RV53 RV61 R400SZ RV500SZ R600SZ 325-3 and 325-5. 101311 for RV81 RV91 RV111 210D 210E 210G 325-7A 325-9. 13A15 13A15-5 13A25 KVOP-3 13A03 PF10 13A09 101310 ACCESSORIES C US 2015 Maxitrol Company. All Rights Reserved. DRAFT 09.18.2013 62 NOTE If vent limiting device is not used regulator vent must be piped in accordance with government and local codes and regulations. RV12L RV20L Integral vent limiting orifice with dust cap standard. RV20VL Integral vent limiting orifice with dust cap standard or use 11A08 threaded sleeve nut and run vent line as per code. RV47 Must order L suffix - Integral vent limiting orifice includes dust cap or D suffix - integral ball-check limiting device includes dust cap. RV48 18 NPT vent tap. Optional 12A04 or 12A06 vent limiter. Optional 13A09 dust cap. Optional 10A16-2 or 10A16-3 plastic thread protector. RV48L Integral vent limiting orifice. RV52 RV53 RV61 18 NPT vent tap. Optional 12A04 or 12A06 vent limiter or 13A15 vent protector. RV81 38 NPT vent tap. Optional 12A34 vent limiter or 13A15-5 vent protector. RV91 2 12 pipe size 14 NPT vent tap. Optional 13A15 vent protector. Vent limiter not approved for this model. RV91 2 pipe size 12 NPT vent tap. 2 pipe size. Optional 13A25 vent protector. Vent limiter not approved for this model. RV111 RV131 34 NPT vent tap. Vent limiter not approved for these models. 210D 38 NPT vent tap. Optional 13A15-5 vent protector. Vent limiter not approved for this model. 210E 12 NPT vent tap. Optional 13A25 vent protector. Vent limiter not approved for this model. 210G 210J 34 NPT vent tap. Vent limiter not approved for these models. 220D 220E 220G 220J Pilot regulator is equipped with 12A06 vent limiting orifice separate vent line is not required. 325-3 325-3L 18 NPT vent tap. Optional 12A09 vent limiting device or 13A15 vent protector. 325-5 325-5L 38 NPT vent tap. Optional 12A39 vent limiting device or 13A15-5 vent protector. 325-7A 325-7AL 12 NPT vent tap. Optional 12A49 vent limiting device or 13A25 vent protector. 325-9 325-9L 12 NPT vent tap. Optional 12A49 vent limiting device or 13A25 vent protector. R400S R500S R600S 18 NPT vent tap. Optional 12A04 vent limiting device. OPD47 Integral vent limiting orifice includes dust cap. OPD48 OPD600 18 NPT vent tap. Optional 12A09 vent limiting device or 13A15 vent protector. OPD210D 38 NPT vent tap. Optional 12A39 vent limiting device or 13A15-5 vent protector. OPD210E 12 NPT vent tap. Optional 12A49 vent limiting device or 13A25 vent protector. NOTICE Maxitrol vent limiting devices eliminate the need to run vent piping to the outside. Vent limiting devices are designed for use indoors and in spaces where limiting the amount of gas escapement due to diaphragm failure is critical. Vent limiting devices should not be used outdoors if they are exposed to the environment. Vent protectors are available for all outdoor applications to ensure proper vent protection. CHOOSING A VENT ACCESSORY Maxitrol Company 23555 Telegraph Rd. PO Box 2230 Southfield MI 48037-2230 GPR_MS_EN_10.2015 www.maxitrol.com 2015 Maxitrol Company All Rights Reserved